Home Neural Network Agilex 7 I-series EMIF toolkit conflicting outcomes

Agilex 7 I-series EMIF toolkit conflicting outcomes

0
Agilex 7 I-series EMIF toolkit conflicting outcomes

[ad_1]

Hi there,  We’ve got a customized board with AGIB022R31B2E1V implementing 4 an identical EMIF interfaces.  When examined with the EMIF toolkit for re-calibration and margining, we acquired conflicting outcomes.   First, each recalibration and site visitors take a look at throughout the toolkit handed. 

colm_1-1710867198326.pngcolm_2-1710867229785.png

Nonetheless, the DQS enter, and DQ enter are all misplaced.  The learn window of 468ps is method over the theoretical 312ps for a 3200Gbps DDR4.

colm_3-1710867357772.png

colm_0-1710866889190.png

 

Vref_In calibration end result can be unconvincing.

colm_4-1710867505328.png

DQS, DQ output and Vref_out calibrations seems to be appropriate.  Similar conduct occurred to all 4 EMIF/DDR4.

 

Reminiscence configurations are:

colm_5-1710867937415.png

 

Does anybody have any thought why the calibration report appears flawed whereas each re-calibration and site visitors take a look at indicated in any other case.

 

[ad_2]